<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-01 09-24-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
90.50 MHz 5/5, 44 dBuV R-HK
Pilot RDS Phase Difference
6.4 kHz 3.1 kHz 64 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 41 kHz 18406 0,3042
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,6 dBr -0,28 dBr 0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-HK " 280A 9 (Varied) 1 0 1 1 9:24, 1.01.2024
RT
"BONNIE TYLER - LOST IN FRANCE "
AF EON
95.3, 96.5 MHz -
FM Scope Max at: 41 kHz MIN: 9 kHz % above 77 kHz: 0,3042 Acquired: 2024/01/01 9:24:16 Total samples: 18406 Equivalent time: 0:15:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,2 dBr MIN: -0,6 dBr AVE: -0,28 dBr % above 0,2 dBr: 0,0 Last value: -0,1 dBr (2024/01/01 9:24:16) 09:10 09:12 09:14 09:16 09:18 09:20 09:22 09:24 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality